{"id":721,"date":"2022-02-16T12:38:01","date_gmt":"2022-02-16T12:38:01","guid":{"rendered":"https:\/\/testing-pipecoatings-kth.de\/?page_id=721"},"modified":"2022-07-13T11:57:27","modified_gmt":"2022-07-13T11:57:27","slug":"korrosionsschutzsysteme","status":"publish","type":"page","link":"https:\/\/testing-pipecoatings-kth.de\/en\/korrosionsschutzsysteme","title":{"rendered":"CORROSION PROTECTION SYSTEMS"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"721\" class=\"elementor elementor-721\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5548dcf8 elementor-section-height-min-height elementor-section-boxed elementor-section-height-default elementor-section-items-middle\" data-id=\"5548dcf8\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;background_motion_fx_motion_fx_scrolling&quot;:&quot;yes&quot;,&quot;background_motion_fx_devices&quot;:[&quot;desktop&quot;,&quot;tablet&quot;,&quot;mobile&quot;]}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-26e78c32\" data-id=\"26e78c32\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-28e167b3 elementor-widget elementor-widget-heading\" data-id=\"28e167b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">KORROSIONS\u00adSCHUTZSYSTEME<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-92350dc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"92350dc\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ca520e2\" data-id=\"ca520e2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-eaeb8d6 elementor-widget elementor-widget-heading\" data-id=\"eaeb8d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">WIR SIND SPEZIALISIERT AUF DIE PR\u00dcFUNG\nFOLGENDER KORROSIONS\u00adSCHUTZSYSTEME:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-852051d elementor-tabs-view-vertical elementor-widget elementor-widget-tabs\" data-id=\"852051d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-tabs\">\n\t\t\t<div class=\"elementor-tabs-wrapper\" role=\"tablist\" >\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1391\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1391\" aria-expanded=\"false\">PE:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1392\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1392\" aria-expanded=\"false\">PP:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1393\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1393\" aria-expanded=\"false\">EP:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1394\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1394\" aria-expanded=\"false\">PUR:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1395\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1395\" aria-expanded=\"false\">ZM:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1396\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1396\" aria-expanded=\"false\">B\u00c4NDER ODER SCHRUMPFF\u00c4HIGES MATERIAL:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1397\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1397\" aria-expanded=\"false\">EMAIL:<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1398\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1398\" aria-expanded=\"false\">GFK:<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t<div class=\"elementor-tabs-content-wrapper\" role=\"tablist\" aria-orientation=\"vertical\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1391\" aria-expanded=\"false\">PE:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1391\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1391\" tabindex=\"0\" hidden=\"false\"><ul>\n \t<li>PE-Umh\u00fcllung von Stahlrohren und Formst\u00fccken<\/li>\n \t<li>3-Lagen<\/li>\n \t<li>DIN 30670, NF A 49-710; UNI 9099; GDF Rv06; prEN 10285; prEN 10287;<\/li>\n \t<li>ISO 21809-1<\/li>\n \t<li>2-Lagen<\/li>\n \t<li>ISO 21809-4<\/li>\n \t<li>PE-Umh\u00fcllung von Gussrohren<\/li>\n \t<li>DIN EN 14 628<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1392\" aria-expanded=\"false\">PP:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1392\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1392\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>PP-Umh\u00fcllung von Stahlrohren, 3-Lagen<\/li>\n \t<li>DIN 30 678; NF A 49711; prEN 10286; ISO 21809-1<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1393\" aria-expanded=\"false\">EP:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1393\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1393\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>EP (Pulver)-Umh\u00fcllung von Stahlrohren<\/li>\n \t<li>DIN 30672; BDI PS \/ CW6-2; CAN \/ CSA Z245.20; ISO 10800<\/li>\n \t<li>EP (fl\u00fcssig)<\/li>\n \t<li>AWWA C210; ISO 21809??<\/li>\n \t<li>EP-innen Gussarmaturen u. Formst\u00fccke<\/li>\n \t<li>DIN 3476<\/li>\n \t<li>EP-Beschichtung<\/li>\n \t<li>DIN 30 677-2; DIN 3476<\/li>\n \t<li>EP-Beschichtung von Gussformst\u00fccken<\/li>\n \t<li>DIN EN 14 901<\/li>\n \t<li>EP (Pulver) Stahlrohre innen<\/li>\n \t<li>ISO 10800<\/li>\n \t<li>EP-Umh\u00fcllung Stahlrohre<\/li>\n \t<li>DIN EN 10289<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"4\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1394\" aria-expanded=\"false\">PUR:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1394\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1394\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>PUR-Umh\u00fcllung von Stahlrohren<\/li>\n \t<li>DIN 30671; NF A 49708; DIN EN 10290; ISO 21809-3<\/li>\n \t<li>PUR-Umh\u00fcllung von Gussrohren<\/li>\n \t<li>NF A 48851; \u00d6NORM B 2560 DIN EN 15655<\/li>\n \t<li>PUR-Beschichtung<\/li>\n \t<li>DIN 30 677-2; DIN 3476<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"5\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1395\" aria-expanded=\"false\">ZM:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1395\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1395\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>ZM-Umh\u00fcllung von Gussrohren<\/li>\n \t<li>DIN 30 674-2<\/li>\n \t<li>ZM-Auskleidung von Stahlrohren<\/li>\n \t<li>DIN EN 10 298; ISO 8324<\/li>\n \t<li>ZM-Auskleidung von Gussrohren<\/li>\n \t<li>DIN EN 545; DIN EN 598<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"6\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1396\" aria-expanded=\"false\">B\u00c4NDER ODER SCHRUMPFF\u00c4HIGES MATERIAL:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1396\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"6\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1396\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>Umh\u00fcllung mit B\u00e4ndern oder schrumpff\u00e4higem Material f\u00fcr Stahlrohre und Gussrohre<\/li>\n \t<li>DIN 30 672 DIN EN 12 068; ISO 21809-3<\/li>\n \t<li>Umh\u00fcllung von Gussrohren mit PE-Folie<\/li>\n \t<li>DIN 30 674-2<\/li>\n \t<li>Umh\u00fcllung von Gussrohren mit Bitumen<\/li>\n \t<li>DIN 30 674-4<\/li>\n \t<li>Umh\u00fcllung von Gussrohren mit Zink\u00fcberzug und Deckbeschichtung<\/li>\n \t<li>DIN 30 674-3<\/li>\n \t<li>Bitumen Umh\u00fcllung Stahlrohre<\/li>\n \t<li>ISO 5256<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"7\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1397\" aria-expanded=\"false\">EMAIL:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1397\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"7\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1397\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>Email-Auskleidungen nach DIN 3475<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"8\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1398\" aria-expanded=\"false\">GFK:<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1398\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"8\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1398\" tabindex=\"0\" hidden=\"hidden\"><ul>\n \t<li>GFK-Umh\u00fcllung als Korrosionsschutz, GFK-Ummantellung als mechanischer Schutz\n<\/li>\n<li>ISO 21809-3, CSA Z245.20, NACE TM 0215 (Gouge-Test), Kundenspezifikationen\n<\/li>\n<\/ul><\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ffda685 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ffda685\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;shape_divider_bottom&quot;:&quot;opacity-tilt&quot;}\">\n\t\t\t\t\t<div class=\"elementor-shape elementor-shape-bottom\" aria-hidden=\"true\" data-negative=\"false\">\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 2600 131.1\" preserveAspectRatio=\"none\">\n\t<path class=\"elementor-shape-fill\" d=\"M0 0L2600 0 2600 69.1 0 0z\"\/>\n\t<path class=\"elementor-shape-fill\" style=\"opacity:0.5\" d=\"M0 0L2600 0 2600 69.1 0 69.1z\"\/>\n\t<path class=\"elementor-shape-fill\" style=\"opacity:0.25\" d=\"M2600 0L0 0 0 130.1 2600 69.1z\"\/>\n<\/svg>\t\t<\/div>\n\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-bb6756f\" data-id=\"bb6756f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5996ccf elementor-widget__width-inherit elementor-widget-mobile__width-inherit elementor-invisible elementor-widget elementor-widget-icon-box\" data-id=\"5996ccf\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeIn&quot;}\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<h3 class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tPR\u00dcFUNG ANDERER SCHUTZSYSTEME AUF ANFRAGE\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/h3>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tBen\u00f6tigen Sie eine Pr\u00fcfung anderer Schutzsysteme? Kontaktieren Sie Korrosionstechnik Heim in Hilden. Gern unterst\u00fctzen wir Sie bei der Pr\u00fcfung neuer Schutzsysteme und beraten Sie umfassend bei Neuentwicklungen.\n\n\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>KORROSIONS\u00adSCHUTZSYSTEME WIR SIND SPEZIALISIERT AUF DIE PR\u00dcFUNG FOLGENDER KORROSIONS\u00adSCHUTZSYSTEME: PE: PP: EP: PUR: ZM: B\u00c4NDER ODER SCHRUMPFF\u00c4HIGES MATERIAL: EMAIL: GFK: PE: PE-Umh\u00fcllung von Stahlrohren und Formst\u00fccken 3-Lagen DIN 30670, NF A 49-710; UNI 9099; GDF Rv06; prEN 10285; prEN 10287; ISO 21809-1 2-Lagen ISO 21809-4 PE-Umh\u00fcllung von Gussrohren DIN EN 14 628 PP: PP-Umh\u00fcllung von [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-721","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KORROSIONS\u00adSCHUTZSYSTEME - Korrosionstechnik Heim<\/title>\n<meta name=\"description\" content=\"Wir sind spezialisiert auf die Pr\u00fcfung verschiedener Korrosionsschutzsysteme und beraten Sie umfassend bei Neuentwicklungen.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/testing-pipecoatings-kth.de\/en\/korrosionsschutzsysteme\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KORROSIONS\u00adSCHUTZSYSTEME - Korrosionstechnik Heim\" \/>\n<meta property=\"og:description\" content=\"Wir sind spezialisiert auf die Pr\u00fcfung verschiedener Korrosionsschutzsysteme und beraten Sie umfassend bei Neuentwicklungen.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/testing-pipecoatings-kth.de\/en\/korrosionsschutzsysteme\/\" \/>\n<meta property=\"og:site_name\" content=\"Korrosionstechnik Heim\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-13T11:57:27+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/korrosionsschutzsysteme\",\"url\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/korrosionsschutzsysteme\",\"name\":\"KORROSIONS\u00adSCHUTZSYSTEME - Korrosionstechnik Heim\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/#website\"},\"datePublished\":\"2022-02-16T12:38:01+00:00\",\"dateModified\":\"2022-07-13T11:57:27+00:00\",\"description\":\"Wir sind spezialisiert auf die Pr\u00fcfung verschiedener Korrosionsschutzsysteme und beraten Sie umfassend bei Neuentwicklungen.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/korrosionsschutzsysteme#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/korrosionsschutzsysteme\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/korrosionsschutzsysteme#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"KORROSIONS\u00adSCHUTZSYSTEME\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/#website\",\"url\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/\",\"name\":\"Korrosionstechnik Heim\",\"description\":\"Ihr Sachverst\u00e4ndiger f\u00fcr Korrosionsschutz in Hilden\",\"publisher\":{\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/#organization\",\"name\":\"Korrosionstechnik Heim\",\"url\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/wp-content\\\/uploads\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/wp-content\\\/uploads\\\/logo.png\",\"width\":161,\"height\":77,\"caption\":\"Korrosionstechnik Heim\"},\"image\":{\"@id\":\"https:\\\/\\\/testing-pipecoatings-kth.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KORROSIONS\u00adSCHUTZSYSTEME - Korrosionstechnik Heim","description":"Wir sind spezialisiert auf die Pr\u00fcfung verschiedener Korrosionsschutzsysteme und beraten Sie umfassend bei Neuentwicklungen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/testing-pipecoatings-kth.de\/en\/korrosionsschutzsysteme\/","og_locale":"en_US","og_type":"article","og_title":"KORROSIONS\u00adSCHUTZSYSTEME - Korrosionstechnik Heim","og_description":"Wir sind spezialisiert auf die Pr\u00fcfung verschiedener Korrosionsschutzsysteme und beraten Sie umfassend bei Neuentwicklungen.","og_url":"https:\/\/testing-pipecoatings-kth.de\/en\/korrosionsschutzsysteme\/","og_site_name":"Korrosionstechnik Heim","article_modified_time":"2022-07-13T11:57:27+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/testing-pipecoatings-kth.de\/korrosionsschutzsysteme","url":"https:\/\/testing-pipecoatings-kth.de\/korrosionsschutzsysteme","name":"KORROSIONS\u00adSCHUTZSYSTEME - Korrosionstechnik Heim","isPartOf":{"@id":"https:\/\/testing-pipecoatings-kth.de\/#website"},"datePublished":"2022-02-16T12:38:01+00:00","dateModified":"2022-07-13T11:57:27+00:00","description":"Wir sind spezialisiert auf die Pr\u00fcfung verschiedener Korrosionsschutzsysteme und beraten Sie umfassend bei Neuentwicklungen.","breadcrumb":{"@id":"https:\/\/testing-pipecoatings-kth.de\/korrosionsschutzsysteme#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/testing-pipecoatings-kth.de\/korrosionsschutzsysteme"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/testing-pipecoatings-kth.de\/korrosionsschutzsysteme#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/testing-pipecoatings-kth.de\/"},{"@type":"ListItem","position":2,"name":"KORROSIONS\u00adSCHUTZSYSTEME"}]},{"@type":"WebSite","@id":"https:\/\/testing-pipecoatings-kth.de\/#website","url":"https:\/\/testing-pipecoatings-kth.de\/","name":"Korrosionstechnik Heim","description":"Ihr Sachverst\u00e4ndiger f\u00fcr Korrosionsschutz in Hilden","publisher":{"@id":"https:\/\/testing-pipecoatings-kth.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/testing-pipecoatings-kth.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en"},{"@type":"Organization","@id":"https:\/\/testing-pipecoatings-kth.de\/#organization","name":"Korrosionstechnik Heim","url":"https:\/\/testing-pipecoatings-kth.de\/","logo":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/testing-pipecoatings-kth.de\/#\/schema\/logo\/image\/","url":"https:\/\/testing-pipecoatings-kth.de\/wp-content\/uploads\/logo.png","contentUrl":"https:\/\/testing-pipecoatings-kth.de\/wp-content\/uploads\/logo.png","width":161,"height":77,"caption":"Korrosionstechnik Heim"},"image":{"@id":"https:\/\/testing-pipecoatings-kth.de\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/pages\/721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/comments?post=721"}],"version-history":[{"count":0,"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/pages\/721\/revisions"}],"wp:attachment":[{"href":"https:\/\/testing-pipecoatings-kth.de\/en\/wp-json\/wp\/v2\/media?parent=721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}